AL-4010 Battery Cell Simulator Module for SLSC

The AL-4010 Battery Cell Simulation Module for SLSC is a 6-cells simulator for applications where you need to validate the functionalities in the BMS and dont want to connect to a real battery pack. The module supports common functionality when testing a BMS such as Charging, Discharge / Cell balancing, Coulomb measurements and Fault Insertion. The board-to-board isolation enables serial connection of the boards to simulate larger battery modules and packs.

Featured functionalities:

  • Charging
  • Discharge / Cell balancing
  • Coulomb measurements
  • Fault Insertion
    • Broken wire
    • Short Circuit
    • Polarity reversal

The board-to-board isolation enables serial connection of the boards to simulate larger battery modules and packs.

Supply and Load

  • Voltage Range: 0 -7V
  • Voltage Accuracy: +/- 1mV
  • Max external load: 2A
  • Current Range: 0-2A
  • Current Accuracy: 2mA

Measurements:

  • Voltage Range: 0 -8V
  • Voltage Accuracy: +/- 1mV
  • Low current range: 0-10mA
  • Low current accuracy: 10µA
  • High current range: +/-2,5A
  • High current accuracy: 2mA
  • Coulomb’s measurement: +/-2,5A

The AL-4010 is a part of the complete xMove Battery Cell Simulator platform where you will be able to completely remove the battery pack from your test environment.

ALIARO is also providing the complete Battery Cell Simulator Rack with Safety Boxes, Power Distribution System and module to emulatate the NTC.

Contact sales for more information.

+ Description

Featured functionalities:

  • Charging
  • Discharge / Cell balancing
  • Coulomb measurements
  • Fault Insertion
    • Broken wire
    • Short Circuit
    • Polarity reversal

The board-to-board isolation enables serial connection of the boards to simulate larger battery modules and packs.

+ Specifications

Supply and Load

  • Voltage Range: 0 -7V
  • Voltage Accuracy: +/- 1mV
  • Max external load: 2A
  • Current Range: 0-2A
  • Current Accuracy: 2mA

Measurements:

  • Voltage Range: 0 -8V
  • Voltage Accuracy: +/- 1mV
  • Low current range: 0-10mA
  • Low current accuracy: 10µA
  • High current range: +/-2,5A
  • High current accuracy: 2mA
  • Coulomb’s measurement: +/-2,5A
+ Applications

The AL-4010 is a part of the complete xMove Battery Cell Simulator platform where you will be able to completely remove the battery pack from your test environment.

ALIARO is also providing the complete Battery Cell Simulator Rack with Safety Boxes, Power Distribution System and module to emulatate the NTC.

Contact sales for more information.

More information

For more information regarding National Instruments SLSC,